“I’m going to be operating the system at (your process temperature here) ºF. How long will the fluid last?”
Maximum Fluid Temperatures
Every heat-transfer-fluid product bulletin shows a maximum recommended operating temperature and/or a maximum recommended film temperature. Many manufacturers simply set the maximum operating temperature by subtracting 50ºF from the maximum recommended film temperature.
Other suppliers, hoping for an advantage, reduce that difference to 20ºF, effectively expanding the fluid’s upper range. The main problem with both approaches is that they ignore the effect that the type of heater has on the actual film temperature.
Heat moves from the heat source (heater tube, electric element or steam coil) through a thin, relatively stagnant film of fluid into the moving fluid. If the temperature of this fluid film exceeds the maximum recommended film temperature, the bonds holding the molecules together start to break apart and the fluid will degrade. But every heater has two film temperatures—the average and the maximum.
The average film temperature is estimated by dividing the average heat flux (BTU/hr-ft2) by the fluid film coefficient (BTU/hr-ft2-ºF) and then adding that number to the operating temperature. The tricky part is estimating the maximum film temperature. If the heater has a uniform heat flux (eg. steam coils, electric element, or fluegas heat recovery) the maximum film temperature will closely track the average.
However, almost all fired heaters have a radiant section (the section where the coils face the flame) which can have a much higher heat flux. This can result in localized film temperatures well in excess of the heater average. Depending on the fired-heater design, temperature differences between bulk and film temperatures can be as high as 100ºF. So if the required operating temperature is within 60-75ºF below the stated maximum film temperature of the heat transfer fluid, be aware that fluid life might be shortened.
Next time we'll cover another commonly reported heat transfer fluid property.

Jim Oetinger
Director of Technology
Paratherm Corporation
|
 |
If you'd like to receive these TipSheets™ on a monthly basis via email,
please enter your name and email below.
(c)2008
Paratherm Corporation
http://www.paratherm.com
Any voluntary information that you choose to share with
Paratherm will remain in our company database and will be shared only
with our technical representatives in order to assist you. Any analysis
of this information we perform is to learn how to better serve our customers,
whether that be through website design, direct contact with customers,
or advertising choices. Your information will never be passed on to any
advertisers or mailing list companies.
|