Paratherm continues the series with "THERMAL FLUID LEAKAGE -- PART 3 OF 3 -- FLASH, FIRE, AND AUTOIGNITION TEMPERATURE DEMYSTIFIED".

Among the topics addressed in future TipSheets will be types of heating for process applications, thermal fluid selection and analysis, heat transfer fluid film coefficient, system selection, design, installation, maintenance and troubleshooting, and cost/benefit analysis.

TipSheet is a service of the Paratherm Corporation. The details are applicable to all heat transfer fluids in closed or vented hot-oil systems.


Parts I and II of this three-part TipSheet™ series covered detecting thermal fluid system leaks, why systems leak, and how to prevent and minimize leaks.

For further background, Part III will discuss the meaning of flash point and related technical terms. We hope this supporting detail will put recommendations from the first two TipSheets in clearer perspective to help you safely maintain your heat transfer fluid system.


PARATHERM TIPSHEET, LEAKAGE PART III: FLASH POINT, FIRE POINT, AND AUTOIGNITION TEMPERATURE DEMYSTIFIED.



FLASH POINT
The lowest temperature at which a heated liquid's vapors when mixed with air can be ignited ("flashed") by a flame or spark, or other ignition source.

FIRE POINT
The lowest temperature at which a heated liquid's vapors burn continuously when combustion is supported by ignition sources such as the above.

AUTOIGNITION TEMPERATURE
The temperature at which the vapor formed by a heated liquid will flash without a source of ignition.

FLASH POINT AND FIRE POINT TESTING
The liquid to be tested is heated in a cup and the rising liquid temperature is continually measured. A small flame is mechanically passed back and forth just above the surface of the liquid. As the liquid gets hotter, more of it evaporates causing the fuel/air mixture above the liquid to gradually become richer. When the lower flammability limit is reached, the ignition source will ignite the vapor/air mixture, causing a pop. The observed temperature when the flame momentarily ignites the vapor/air mixture is the Flash Point. The ignitions repeat as the liquid temperature continues to rise. The observed temperature when the burning becomes continuous is the Fire Point.

AUTOIGNITION TEMPERATURE TEST
A sample is injected into a flask which is heated to the test temperature. If a “flash” is observed in the container, that temperature is the Auto Ignition Temperature. IF no flash is observed after a period of time, the flask temperature is increased and the test repeated. This method (ASTM E659-78) is valid only for fluids that are completely vaporized at the test temperature since the degradation products formed by any remaining liquid will affect the test result.

SO, THREE CONDITIONS TO BE AWARE OF:

For a flash-point-related fire to occur, all three of the following conditions must be met:

1) Vapor concentration – These combustion tests allow vapor to concentrate. In real life, the vapors turn to smoke as they encounter air and dissipate.


2) Temperature – Thermal oils cool rapidly when exposed to air.


3) Source of ignition – Thermal-fluid leaks are difficult to ignite unless a significant amount of very hot fluid leaks into a closed area where inadequate ventilation allows unreacted vapor to collect and mix with air. An exception occurs when fluid leaks onto an extremely hot surface such as the housing of a pump that is failing, or a rotary union that has seized. Technically, this is not a flash-point-related problem but one of autoignition.


Heat Transfer Fluids in closed-loop systems, whether natural or synthetic, are routinely used well in excess of their flash and fire points.

For more technical data on System Leakage contact our engineering staff at
+1-610-941-4900, or go to:

Technical Data Sheet: Leakage in Thermal Oil
Systems, Flash and Fire Points Demystified

Visitors

Members


If you'd like to receive these TipSheets™ on a monthly basis via email,
please enter your name and email below.

Subscribe Now!

Your Name:
Your E-mail Address:




(c)2003 Paratherm Corporation
http://www.paratherm.com

Any voluntary information that you choose to share with Paratherm will remain in our company database and will be shared only with our technical representatives in order to assist you. Any analysis of this information we perform is to learn how to better serve our customers, whether that be through website design, direct contact with customers, or advertising choices. Your information will never be passed on to any advertisers or mailing list companies.

 

 

 
whitespacer.gif
whitespacer.gif
whitespacer.gif

HEAT TRANSFER
FLUIDS

SYSTEM CLEANERS

SAFETY

AVAILABILITY

USER'S GUIDE

NEWS & MEDIA

ESPAÑOL

INTERNATIONAL

TIP SHEET

ORDER

HOME

Search

 

   [Home][About Us] [Contact Us] [Site Map] [Privacy Policy] [Top]

Paratherm Corporation | 4 Portland Road | West Conshohocken, PA 19428 USA | Toll-Free in USA and Canada: +1 800-222-3611